Windows Deployment Notes
Running ComfyUI + OpenClaw on Windows, especially with the Portable version.
Environment Variables
Portable Version (run_nvidia_gpu.bat)
To set OpenClaw security tokens in the portable version, edit your run_nvidia_gpu.bat (or create a wrapper run_openclaw.bat):
@echo off
:: Security Tokens
set OPENCLAW_ADMIN_TOKEN=my-secret-token
set OPENCLAW_ALLOW_REMOTE_ADMIN=1
set OPENCLAW_OBSERVABILITY_TOKEN=observability-token
set OPENCLAW_LOG_TRUNCATE_ON_START=1
:: Run ComfyUI
.\python_embeded\python.exe -s ComfyUI\main.py --windows-standalone-build
pause
PowerShell
$env:OPENCLAW_ADMIN_TOKEN="my-secret-token"
$env:OPENCLAW_ALLOW_REMOTE_ADMIN="1"
$env:OPENCLAW_LOG_TRUNCATE_ON_START="1"
./python_embeded/python.exe -s ComfyUI/main.py
LAN / Mobile Remote Admin Startup
If you want to open the standalone remote admin page from another device in your LAN:
$env:OPENCLAW_ADMIN_TOKEN="my-secret-token"
$env:OPENCLAW_ALLOW_REMOTE_ADMIN="1"
$env:OPENCLAW_LOG_TRUNCATE_ON_START="1"
./python_embeded/python.exe -s ComfyUI/main.py --listen 0.0.0.0 --port 8188
Then open from phone/tablet browser:
http://<WINDOWS_LAN_IP>:8188/openclaw/admin
Find your LAN IP:
ipconfig
Service Mode (NSSM)
If you want to run ComfyUI as a background service, use NSSM (Non-Sucking Service Manager).
- Download NSSM.
nssm install ComfyUI- Application: Path to python.exe (or bat file).
- Environment: Add tokens here in the Environment tab (Input:
KEY=VALUEper line). - I/O: Redirect stdout/stderr to logs so you can debug startup issues.
Caveats
- Permissions: Services run as
SYSTEMby default. It is safer to create a dedicated user and set the service to Log On as that user. - GPU Access: Ensure the user running the service has access to the GPU driver context (usually fine for logged-in users, tricky for headless services).
Common Startup Failure: WinError 10013
Symptom:
PermissionError: [WinError 10013] ... bind on address ('0.0.0.0', 8188)
Typical causes:
- Port is already occupied by another process.
- Firewall/security policy blocks this bind.
- Reserved/excluded port range on Windows.
Deterministic remediation:
- Retry with another port (for example
--port 8200). - Ensure no duplicate ComfyUI instance is already listening.
- Verify inbound firewall rule allows the selected port for
LocalSubnet. - If still failing, check excluded ranges and avoid those ports:
netsh int ipv4 show excludedportrange protocol=tcp